Dark Reading is part of the Informa Tech Division of Informa PLC

This site is operated by a business or businesses owned by Informa PLC and all copyright resides with them.Informa PLC's registered office is 5 Howick Place, London SW1P 1WG. Registered in England and Wales. Number 8860726.

Vulnerabilities / Threats

8/10/2016
05:45 PM
Connect Directly
Twitter
LinkedIn
RSS
E-Mail
50%
50%

PLC Worms Pose Stealthy Threat To Industrial Systems

Researchers at Black Hat USA demonstrated 'PLC Blaster' worm capable of infecting programmable logic controllers and spreading to other systems.

Attacks on programmable logic controllers (PLCS) -- the systems used to automate the control of industrial equipment -- can have devastating physical consequences as Stuxnet demonstrated in 2010 when it was used to sabotage uranium-enriching centrifuges at Iran’s Natanz nuclear facility.

Stuxnet's attackers took advantage of several Microsoft Windows vulnerabilities to compromise PCs across the facility, which were then used to tamper with the PLCs.

Security researchers at Black Hat USA in Las Vegas last week demonstrated how a similar attack could be pulled off using a worm residing entirely in the PLC itself and capable of spreading to other controllers -- without a PC or external help. Such worms can be very hard to detect using traditional anti-virus tools and can be easily missed by PLC operators.

The problem, according to researchers Ralf Spenneberg and Maik Bruggemann of OpenSource Security, is that some PLC models allow unauthenticated changes to the user programs, or instructions that are used to control connected equipment. In such cases, it is possible for an attacker with the right know-how to insert code into the PLC that causes connected equipment to behave erratically or to fail entirely.

The researchers used a Siemens S7-1200 PLC system connected to a small piece of industrial equipment for the demonstration. They showed how an attacker could introduce malicious code into the system and get the PLC to issue commands for disrupting the operation of the connected machinery. They also had the infected system search for and infect other PLC systems on the same network.

The demonstration began with the worm scanning a mock industrial network for the presence of Siemens S7-1200 systems and detecting them from their associated TCP number. The researchers showed how the worm could then replicate itself on the target system by mimicking a legitimate process for software changes. Once on a PLC, the worm is designed to scan for and infect other PLCs on its own, they said.

In addition, the PLC Blaster worm used in the demonstration was designed to communicate over TCP with remote a command and control server and receive commands from it.

The hardest part of the attack, according to Spenneberg and Bruggemann, was figuring out the protocol used by the Siemens PLCs to communicate with each other PLC systems. There is no publicly available documentation on how the protocol works,, so the researchers had to adopt their own methods to try and extract the information. Once the protocol was cracked, the rest of the infection and worm propagation was relatively straightforward.

The Siemens PLC chosen for the demonstration offered several anti-tamper mechanisms, the researchers said. For instance the system is designed to prevent unauthorized modifications of the code, is password-protected, and uses AES to encrypt source code. A function called Copy Protection binds user program to specific PLCs, while another access control feature limits the features on the PLC that can be used without a password.

But most of the protections are insufficient and only protects exiting code. They do not fully stop attackers from introducing code modifying the behavior of the PLCs.

According to the researchers, the Siemens model that was used for the demonstration is not the only PLC that is susceptible to such tampering. Many PLCs that have programmable TCP functions support data transfer via TCP and are on an industrial Ethernet are vulnerable, according to them. But the researchers have not tested any of the other models, and therefore are not sure how well the mitigation measures on each of these devices work.

 

Jai Vijayan is a seasoned technology reporter with over 20 years of experience in IT trade journalism. He was most recently a Senior Editor at Computerworld, where he covered information security and data privacy issues for the publication. Over the course of his 20-year ... View Full Bio

Comment  | 
Print  | 
More Insights
Comments
Newest First  |  Oldest First  |  Threaded View
Microsoft Patches Wormable RCE Vulns in Remote Desktop Services
Kelly Sheridan, Staff Editor, Dark Reading,  8/13/2019
The Mainframe Is Seeing a Resurgence. Is Security Keeping Pace?
Ray Overby, Co-Founder & President at Key Resources, Inc.,  8/15/2019
GitHub Named in Capital One Breach Lawsuit
Dark Reading Staff 8/14/2019
Register for Dark Reading Newsletters
White Papers
Video
Cartoon Contest
Write a Caption, Win a Starbucks Card! Click Here
Latest Comment: This comment is waiting for review by our moderators.
Current Issue
7 Threats & Disruptive Forces Changing the Face of Cybersecurity
This Dark Reading Tech Digest gives an in-depth look at the biggest emerging threats and disruptive forces that are changing the face of cybersecurity today.
Flash Poll
The State of IT Operations and Cybersecurity Operations
The State of IT Operations and Cybersecurity Operations
Your enterprise's cyber risk may depend upon the relationship between the IT team and the security team. Heres some insight on what's working and what isn't in the data center.
Twitter Feed
Dark Reading - Bug Report
Bug Report
Enterprise Vulnerabilities
From DHS/US-CERT's National Vulnerability Database
CVE-2019-15150
PUBLISHED: 2019-08-19
In the OAuth2 Client extension before 0.4 for MediaWiki, a CSRF vulnerability exists due to the OAuth2 state parameter not being checked in the callback function.
CVE-2017-18550
PUBLISHED: 2019-08-19
An issue was discovered in drivers/scsi/aacraid/commctrl.c in the Linux kernel before 4.13. There is potential exposure of kernel stack memory because aac_get_hba_info does not initialize the hbainfo structure.
CVE-2017-18551
PUBLISHED: 2019-08-19
An issue was discovered in drivers/i2c/i2c-core-smbus.c in the Linux kernel before 4.14.15. There is an out of bounds write in the function i2c_smbus_xfer_emulated.
CVE-2017-18552
PUBLISHED: 2019-08-19
An issue was discovered in net/rds/af_rds.c in the Linux kernel before 4.11. There is an out of bounds write and read in the function rds_recv_track_latency.
CVE-2018-20976
PUBLISHED: 2019-08-19
An issue was discovered in fs/xfs/xfs_super.c in the Linux kernel before 4.18. A use after free exists, related to xfs_fs_fill_super failure.