Schneider Electric Offers Additional Details on Triton Malware

In December, FireEye and Symantec disclosed details about the Triton malware, which targets industrial systems. Now, Schneider Electric is offering additional details.

In December, security researchers identified a new malware dubbed Triton, which targets industrial systems and could have its origins with a nation state. Now, Schneider Electric is shining a light on some additional details about the trojan.

In a notice that went out this week, [company link 14006 not found] noted that it's working with one of its customers to address the issue and is also in contact with outside security vendors, as well as the US Department of Homeland Security.

While Triton is only known to have only infected one facility in the Middle East, the name of the victim company has not been released.

The Triton trojan targets Triconex Safety Instrumented System (SIS) controllers that are made by Schneider. These SIS controllers provide emergency shutdown capabilities for large industrial complexes and by targeting this part of the infrastructure, the malware can cause physical damage to the facility.

FireEye Inc. and Symantec Corp. (Nasdaq: SYMC) each published research reports on Triton in December. (See FireEye Researchers Identify Triton Malware in Industrial Systems.)

On January 18, Schneider released its own security bulletin about Triton, noting that the company has not detected any damage from the attack.

However, the security bulletin noted that the Triton malware targeted the Tricon firmware, which is part of the Triconex SIS controller, although this was limited to a small number of older versions of this particular firmware, according to the company.

Schneider noted that Triton requires unrestricted access to the safety network and this can be done either through a remote network or by gaining physical access. In addition, the trojan requires that a key switch needs to be left in "program" mode in order for the malware to deploy its payload.


The fundamentals of network security are being redefined – don't get left in the dark by a DDoS attack! Join us in Austin from May 14-16 at the fifth annual Big Communications Event. There's still time to register and communications service providers get in free!

"This vulnerability was a part of a complex malware infection scenario," according to Schneider's bulletin. "To date, the information gathered indicates that if the Tricon key switch had been left in the correct position per our recommended guidelines, the injection of malware would not have been successful."

Triton is referred to as a Remotely Accessible Trojan (RAT), which can control a network connection. In this case, the malware has the ability to scan and map the industrial control system or ICS and then provide that information back to its creators. It can also issue commands to the Tricon controllers, which can wreak chaos with the safety system and damage a plant or shut it down.

Right now, it's not known who or what is Triton, but in previous reports, security researchers noted the malware acts in the same as Stuxnet was used against Iran in 2010 and Industroyer was deployed against Ukraine in 2016. What's not known is if the trojan was meant to spy on the facility or actually case a massive shut down and damage.

As part of its bulletin, Schneider is planning to release a tool that will detect Triton in the Tricon controller and will remove the malware if it's discovered. The company plans to release this update in February.

Related posts:

— Scott Ferguson, Editor, Enterprise Cloud News. Follow him on Twitter @sferguson_LR.

Comment  | 
Print  | 
More Insights
Comments
Newest First  |  Oldest First  |  Threaded View
Edge-DRsplash-10-edge-articles
I Smell a RAT! New Cybersecurity Threats for the Crypto Industry
David Trepp, Partner, IT Assurance with accounting and advisory firm BPM LLP,  7/9/2021
News
Attacks on Kaseya Servers Led to Ransomware in Less Than 2 Hours
Robert Lemos, Contributing Writer,  7/7/2021
Commentary
It's in the Game (but It Shouldn't Be)
Tal Memran, Cybersecurity Expert, CYE,  7/9/2021
Register for Dark Reading Newsletters
White Papers
Video
Cartoon
Current Issue
The 10 Most Impactful Types of Vulnerabilities for Enterprises Today
Managing system vulnerabilities is one of the old est - and most frustrating - security challenges that enterprise defenders face. Every software application and hardware device ships with intrinsic flaws - flaws that, if critical enough, attackers can exploit from anywhere in the world. It's crucial that defenders take stock of what areas of the tech stack have the most emerging, and critical, vulnerabilities they must manage. It's not just zero day vulnerabilities. Consider that CISA's Known Exploited Vulnerabilities (KEV) catalog lists vulnerabilitlies in widely used applications that are "actively exploited," and most of them are flaws that were discovered several years ago and have been fixed. There are also emerging vulnerabilities in 5G networks, cloud infrastructure, Edge applications, and firmwares to consider.
Flash Poll
Twitter Feed
Dark Reading - Bug Report
Bug Report
Enterprise Vulnerabilities
From DHS/US-CERT's National Vulnerability Database
CVE-2023-1142
PUBLISHED: 2023-03-27
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation.
CVE-2023-1143
PUBLISHED: 2023-03-27
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code.
CVE-2023-1144
PUBLISHED: 2023-03-27
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation.
CVE-2023-1145
PUBLISHED: 2023-03-27
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.
CVE-2023-1655
PUBLISHED: 2023-03-27
Heap-based Buffer Overflow in GitHub repository gpac/gpac prior to 2.4.0.